![]() |
Nom De Marque: | YOKOGAWA |
Numéro De Modèle: | GS820 |
Nombre De Pièces: | 1 set |
Prix: | Négociable |
Conditions De Paiement: | T / t |
YOKOGAWA GS820 Multi Channel Source Measure Unit
Description of YOKOGAWA GS820
Four-quadrant operation consisting of source operation (current source) and sink operation (current sink) is available with ranges up to 7 V and 3.2 A or 18 V and 1.2 A. The output and measurement resolutions are 5.5 digits. Other features include:
18V model: 7 V and 3.2 A or 18 V and 1.2 A
50V model: 20 V and 1.2 A or 50 V and 0.6 A
Source and Measurement Range
Four-quadrant operation consisting of source operation (current source) and sink operation (current sink) is available. The output and measurement resolutions are 5.5 digits. Two models are available for your application.
18 V model (765601/02)
200 mV, 2 V, 7 V, and 18 V
±3.2 A (at an output voltage of ±7 V or less) ±1.2 A (at an output voltage of ±18 V or less)
Current ranges:
200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA, 200 mA, 1 A, and 3 A
Maximum output voltage:
±18 V (at an output current of ±1.2 A or less) ±7 V (at an output current of ±3.2 A or less)
50 V model (765611/12)
Voltage ranges:
200 mV, 2 V, 20 V, and 50 V
Maximum output current:
±1.2 A (at an output voltage of ±20 V or less) ±0.6 A (at an output voltage of ±50 V or less)
200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA, 200 mA, 0.5 A, and 1 A
Maximum output voltage:
±50 V (at an output current of ±0.6 A or less) ±20 V (at an output current of ±1.2 A or less)
Construction and Functions of YOKOGAWA GS820
The GS820 is equipped with two analog channels with each channel consisting of a constant voltage source VS, a constant current source IS, a voltmeter VM, and an ammeter IM.
The two source measure channels are isolated.
Source and Measurement Functions
These functions can be selected for each channel to form an arbitrary combination of functions.
Allows voltage sensing of a two-wire system or four-wire system by switching between local sense and remote sense.
*1: Device Under Test
*2: For DUT voltage measurement
Combination of Source and Measurement Functions
The combination of the source and measurement functions of two channels allows the testing of various DUTs.
Source and Measurement Timing
Basic Source Measurement Timing
The GS820 performs generation and measurement using its internal timer or a trigger input such as an external input signal. When a trigger signal is received, the GS820 starts generating a signal after the source delay time elapses and carries out a measurement after the measure delay time elapses over a given integration time. The measurement integration time can be set in the range of 0.001 PLC to 25 PLC.*² Additionally, the GS820 provides an auto zero measurement function, which measures the internal zero reference after the measurement and performs offset correction in real-time. The integration time of the auto zero measurement is equal to the measurement integration time setting.
Timing Settings Using Various Trigger Sources
The GS820 allows the generation trigger source and measurement trigger source to be set separately. There are two types of constant period timers and an external signal input that can be used for the generation trigger source. In addition to these sources, source change point and sweep end point can be used for the measurement trigger source. Because the source trigger and measurement trigger can be set separately and also separately for each channel, source and measurement under various connection conditions and timing combinations can be accommodated. There is also an auxiliary trigger that can be activated using an external signal or a program event. The source delay, measure delay, and integration time can be set separately for each channel.
Asynchronous Operation of Source and Measure
The various trigger sources available on the GS820 allow the source and measurement to be executed asynchronously. The figure below shows an example in which separate timers are used for the source and measurement to achieve multiple measurements in a source cycle.
Sweep Function 1: Preset Sweep
The voltage/current generation block of the GS820 operates in DC generation mode or pulse generation mode. Each generation mode has preset operation modes such as continuous output, linear sweep, and log sweep that allow the user to perform sweep operations by setting simple parameters. The output level can be changed at a minimum of 100-µs intervals*¹ in each sweep mode.
*1: Minimum program cycle
100 µs: If the measurement function is OFF
500 µs: If the measurement function is ON, two channels are used, and auto zero is OFF
Sweep Function 2: Arbitrary Waveform Generation of Up to 100,000 Points and Simultaneous Sweeping of Control Parameters
*1: Minimum program cycle
100 µs: If the measurement function is OFF
500 µs: If the measurement function is ON, two channels are used, and auto zero is OFF
The values do not include the hardware operation time corresponding to the control parameters.
Control parameters that can be included in a sweep program
Test Sequence Editing(Application to auto testing equipment)
The GS820 allows the editing of test sequences suitable for auto testing on the production lines. A user can write program fi le parameters that are vital to auto testing such as the source value, measured value, high limit for comparison, low limit for comparison, comparison result, control bit output, etc. Because the program fi le is in CSV format, a popular spreadsheet application can be used to edit and view the program.
Example of a measurement result file
Test Speed (Improvement in the Takt Time in the Production Line Test)
The GS820 provides fast operation for production line tests. The measured results of test speeds (reference data) are indicated below.
Measured values of test speeds (reference data)
Channel Expansion(Expansion up to 10 channels using the master-slave operation)
Multiple GS820s can be connected as shown below and used as a multi-channel source measure unit. The master-slave feature allows the program data of all connected channels to be set and collected by simply accessing the master unit. The master unit (1) distributes the source data to the slave units or (2) collects and merges the measured data of all slave units. Complete synchronization of all channels can be achieved by connecting the exclusive trigger signal line.
Zero Generation Function of Voltage and Current(Fast load disconnection without chattering)
The zero generation function of the GS820 generates zero voltage or current as well as controls the current/voltage limiter to limit the load current. The GS820 stops applying the voltage or supplying the current to the load in the zero generation state allowing the DUT to be disconnected with the output relay turned ON. This function avoids the problems of chattering and contact life of the output relay and reduces the time for turning ON/OFF the output.
Our service:
1.One-stop service from manufacture to shipping.
2.Your inquiry related to our products or prices will be replied in 24hours.
3.Well-trained and experienced staffs to answer all your enquires influent English.
4.Distributor ship is offered for your unique desigh and some our current models.
5.Protection of your sales area, ideas of design and all your private information.
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below.
|
Nom De Marque: | YOKOGAWA |
Numéro De Modèle: | GS820 |
Nombre De Pièces: | 1 set |
Prix: | Négociable |
Conditions De Paiement: | T / t |
YOKOGAWA GS820 Multi Channel Source Measure Unit
Description of YOKOGAWA GS820
Four-quadrant operation consisting of source operation (current source) and sink operation (current sink) is available with ranges up to 7 V and 3.2 A or 18 V and 1.2 A. The output and measurement resolutions are 5.5 digits. Other features include:
18V model: 7 V and 3.2 A or 18 V and 1.2 A
50V model: 20 V and 1.2 A or 50 V and 0.6 A
Source and Measurement Range
Four-quadrant operation consisting of source operation (current source) and sink operation (current sink) is available. The output and measurement resolutions are 5.5 digits. Two models are available for your application.
18 V model (765601/02)
200 mV, 2 V, 7 V, and 18 V
±3.2 A (at an output voltage of ±7 V or less) ±1.2 A (at an output voltage of ±18 V or less)
Current ranges:
200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA, 200 mA, 1 A, and 3 A
Maximum output voltage:
±18 V (at an output current of ±1.2 A or less) ±7 V (at an output current of ±3.2 A or less)
50 V model (765611/12)
Voltage ranges:
200 mV, 2 V, 20 V, and 50 V
Maximum output current:
±1.2 A (at an output voltage of ±20 V or less) ±0.6 A (at an output voltage of ±50 V or less)
200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA, 200 mA, 0.5 A, and 1 A
Maximum output voltage:
±50 V (at an output current of ±0.6 A or less) ±20 V (at an output current of ±1.2 A or less)
Construction and Functions of YOKOGAWA GS820
The GS820 is equipped with two analog channels with each channel consisting of a constant voltage source VS, a constant current source IS, a voltmeter VM, and an ammeter IM.
The two source measure channels are isolated.
Source and Measurement Functions
These functions can be selected for each channel to form an arbitrary combination of functions.
Allows voltage sensing of a two-wire system or four-wire system by switching between local sense and remote sense.
*1: Device Under Test
*2: For DUT voltage measurement
Combination of Source and Measurement Functions
The combination of the source and measurement functions of two channels allows the testing of various DUTs.
Source and Measurement Timing
Basic Source Measurement Timing
The GS820 performs generation and measurement using its internal timer or a trigger input such as an external input signal. When a trigger signal is received, the GS820 starts generating a signal after the source delay time elapses and carries out a measurement after the measure delay time elapses over a given integration time. The measurement integration time can be set in the range of 0.001 PLC to 25 PLC.*² Additionally, the GS820 provides an auto zero measurement function, which measures the internal zero reference after the measurement and performs offset correction in real-time. The integration time of the auto zero measurement is equal to the measurement integration time setting.
Timing Settings Using Various Trigger Sources
The GS820 allows the generation trigger source and measurement trigger source to be set separately. There are two types of constant period timers and an external signal input that can be used for the generation trigger source. In addition to these sources, source change point and sweep end point can be used for the measurement trigger source. Because the source trigger and measurement trigger can be set separately and also separately for each channel, source and measurement under various connection conditions and timing combinations can be accommodated. There is also an auxiliary trigger that can be activated using an external signal or a program event. The source delay, measure delay, and integration time can be set separately for each channel.
Asynchronous Operation of Source and Measure
The various trigger sources available on the GS820 allow the source and measurement to be executed asynchronously. The figure below shows an example in which separate timers are used for the source and measurement to achieve multiple measurements in a source cycle.
Sweep Function 1: Preset Sweep
The voltage/current generation block of the GS820 operates in DC generation mode or pulse generation mode. Each generation mode has preset operation modes such as continuous output, linear sweep, and log sweep that allow the user to perform sweep operations by setting simple parameters. The output level can be changed at a minimum of 100-µs intervals*¹ in each sweep mode.
*1: Minimum program cycle
100 µs: If the measurement function is OFF
500 µs: If the measurement function is ON, two channels are used, and auto zero is OFF
Sweep Function 2: Arbitrary Waveform Generation of Up to 100,000 Points and Simultaneous Sweeping of Control Parameters
*1: Minimum program cycle
100 µs: If the measurement function is OFF
500 µs: If the measurement function is ON, two channels are used, and auto zero is OFF
The values do not include the hardware operation time corresponding to the control parameters.
Control parameters that can be included in a sweep program
Test Sequence Editing(Application to auto testing equipment)
The GS820 allows the editing of test sequences suitable for auto testing on the production lines. A user can write program fi le parameters that are vital to auto testing such as the source value, measured value, high limit for comparison, low limit for comparison, comparison result, control bit output, etc. Because the program fi le is in CSV format, a popular spreadsheet application can be used to edit and view the program.
Example of a measurement result file
Test Speed (Improvement in the Takt Time in the Production Line Test)
The GS820 provides fast operation for production line tests. The measured results of test speeds (reference data) are indicated below.
Measured values of test speeds (reference data)
Channel Expansion(Expansion up to 10 channels using the master-slave operation)
Multiple GS820s can be connected as shown below and used as a multi-channel source measure unit. The master-slave feature allows the program data of all connected channels to be set and collected by simply accessing the master unit. The master unit (1) distributes the source data to the slave units or (2) collects and merges the measured data of all slave units. Complete synchronization of all channels can be achieved by connecting the exclusive trigger signal line.
Zero Generation Function of Voltage and Current(Fast load disconnection without chattering)
The zero generation function of the GS820 generates zero voltage or current as well as controls the current/voltage limiter to limit the load current. The GS820 stops applying the voltage or supplying the current to the load in the zero generation state allowing the DUT to be disconnected with the output relay turned ON. This function avoids the problems of chattering and contact life of the output relay and reduces the time for turning ON/OFF the output.
Our service:
1.One-stop service from manufacture to shipping.
2.Your inquiry related to our products or prices will be replied in 24hours.
3.Well-trained and experienced staffs to answer all your enquires influent English.
4.Distributor ship is offered for your unique desigh and some our current models.
5.Protection of your sales area, ideas of design and all your private information.
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below.